Centre de Documentation Campus Montignies
Horaires :
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Bienvenue sur le catalogue du centre de documentation du campus de Montignies.
Détail de l'auteur
Auteur Robert Lindeboom |
Documents disponibles écrits par cet auteur



Comparison between the Harris- and Oxford Hip Score to evaluate outcomes one-year after total hip arthroplasty / Hanneke Weel in Acta Orthopaedica Belgica, Vol.83/1 (Mars 2017)
[article]
Titre : Comparison between the Harris- and Oxford Hip Score to evaluate outcomes one-year after total hip arthroplasty Type de document : texte imprimé Auteurs : Hanneke Weel, Auteur ; Robert Lindeboom, Auteur Année de publication : 2017 Article en page(s) : p. 98-109 Langues : Anglais (eng) Résumé : Harris Hip Score (HHS) is a surgeon administered measurement for assessing hip function before and after total hip arthroplasties (THA). Patient reported outcome measurements (PROMs) such as the Oxford Hip Score (OHS) are in-creasingly used. HHS was compaired to the OHS assessing whether the HHS can be replaced by the OHS for clinical eval-uation of THAs. All 155 patients (167 THAs) were asked to complete an OHS before and one-year after surgery. The surgeon independently scored the HHS at the same time points. We examined and compared the clinimetric properties of both instruments. Internal consistency reliability of the OHS was notably higher than that of the HHS at all occasions. HHS had a higher effect size (4.1) than the OHS (2.1). Ceiling effect at follow up was 55.6% (HHS) and 36.4% (OHS). Spearman's rank correlation between HHS and OHS was 0.57 at baseline and 0.65 and after one year. The correlation between the change scores was 0.50. The Oxford Hip Score is of good use in quality assessment after THA. Permalink : ./index.php?lvl=notice_display&id=92975
in Acta Orthopaedica Belgica > Vol.83/1 (Mars 2017) . - p. 98-109[article] Comparison between the Harris- and Oxford Hip Score to evaluate outcomes one-year after total hip arthroplasty [texte imprimé] / Hanneke Weel, Auteur ; Robert Lindeboom, Auteur . - 2017 . - p. 98-109.
Langues : Anglais (eng)
in Acta Orthopaedica Belgica > Vol.83/1 (Mars 2017) . - p. 98-109
Résumé : Harris Hip Score (HHS) is a surgeon administered measurement for assessing hip function before and after total hip arthroplasties (THA). Patient reported outcome measurements (PROMs) such as the Oxford Hip Score (OHS) are in-creasingly used. HHS was compaired to the OHS assessing whether the HHS can be replaced by the OHS for clinical eval-uation of THAs. All 155 patients (167 THAs) were asked to complete an OHS before and one-year after surgery. The surgeon independently scored the HHS at the same time points. We examined and compared the clinimetric properties of both instruments. Internal consistency reliability of the OHS was notably higher than that of the HHS at all occasions. HHS had a higher effect size (4.1) than the OHS (2.1). Ceiling effect at follow up was 55.6% (HHS) and 36.4% (OHS). Spearman's rank correlation between HHS and OHS was 0.57 at baseline and 0.65 and after one year. The correlation between the change scores was 0.50. The Oxford Hip Score is of good use in quality assessment after THA. Permalink : ./index.php?lvl=notice_display&id=92975 Exemplaires
Cote Support Localisation Section Disponibilité aucun exemplaire