Centre de Documentation Campus Montignies
Horaires :
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Bienvenue sur le catalogue du centre de documentation du campus de Montignies.
Détail de l'auteur
Auteur Gunnar Huebner |
Documents disponibles écrits par cet auteur



Device for the local radiation of tumor-bearing laboratory rodents. / Gunnar Huebner in LabAnimal-Europe, 3/10 (mars 2010)
[article]
Titre : Device for the local radiation of tumor-bearing laboratory rodents. Type de document : texte imprimé Auteurs : Gunnar Huebner Année de publication : 2010 Article en page(s) : p. 32-35 Langues : Anglais (eng) Résumé : Since no standard method for reproducibly irradiating local tumors of laboratory rodents exists, the authors designed a device to accurately irradiate rodent tumors. Laboratory personnel can easily assemble this inexpensive device. The new device delivers highly focused treatment and avoids the need for anesthesia and sedation. It represents an improvement over former improvised procedures done at the authors' institutions, because it allows for more accurate irradiation of rodent tumors. The authors used the device to irradiate single tumors on the left hind legs of 60 mice and 10 rats with a dosage of 7 gray (Gy) ionizing radiation. At time of irradiation, the clinical condition of the animals was very poor, but all animals survived the treatment. Permalink : ./index.php?lvl=notice_display&id=76471
in LabAnimal-Europe > 3/10 (mars 2010) . - p. 32-35[article] Device for the local radiation of tumor-bearing laboratory rodents. [texte imprimé] / Gunnar Huebner . - 2010 . - p. 32-35.
Langues : Anglais (eng)
in LabAnimal-Europe > 3/10 (mars 2010) . - p. 32-35
Résumé : Since no standard method for reproducibly irradiating local tumors of laboratory rodents exists, the authors designed a device to accurately irradiate rodent tumors. Laboratory personnel can easily assemble this inexpensive device. The new device delivers highly focused treatment and avoids the need for anesthesia and sedation. It represents an improvement over former improvised procedures done at the authors' institutions, because it allows for more accurate irradiation of rodent tumors. The authors used the device to irradiate single tumors on the left hind legs of 60 mice and 10 rats with a dosage of 7 gray (Gy) ionizing radiation. At time of irradiation, the clinical condition of the animals was very poor, but all animals survived the treatment. Permalink : ./index.php?lvl=notice_display&id=76471 Réservation
Réserver ce document
Exemplaires (1)
Cote Support Localisation Section Disponibilité Revue Revue Centre de Documentation HELHa Campus Montignies Réserve Empruntable sur demande auprès des documentalistes
Disponible