Centre de Documentation Campus Montignies
Horaires :
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Bienvenue sur le catalogue du centre de documentation du campus de Montignies.
[article]
Titre : |
Are there differences in Hip Biomechanics after hybrid and cementless resurfacing arthroplasty? |
Type de document : |
texte imprimé |
Auteurs : |
Michel J. Le Duff ; Sandeep K. Bhaurla ; Kohtaroh B. Takamura ; Harlan Amstutz (C.) |
Année de publication : |
2016 |
Article en page(s) : |
p. 516-521 |
Langues : |
Anglais (eng) |
Mots-clés : |
arthroplastie hanche |
Résumé : |
There is a paucity of information regarding the clinical performance of the fully cementless metalon-metal hip resurfacing designs. We compared the biomechanical reconstruction between the two hips of a group of patients treated with a hybrid resurfacing design on one side and a new, fully cementless version of the same resurfacing design on the other side. We retrospectively identified 20 patients with a hybrid hip resurfacing on one side and a fully cementless device on the contralateral side. The cemented femoral components were implanted with a target angle stem to shaft angle of 140° while the cementless femoral components were implanted with the aim to replicate the natural neck to shaft angle. No significant differences were observed postoperatively in femoral offset or leg length despite implantation with a larger metaphyseal stem to femoral shaft angle in the hybrid group. Both hybrid and cementless designs provide similar biomechanical reconstructions. |
Permalink : |
./index.php?lvl=notice_display&id=47179 |
in Acta Orthopaedica Belgica > Vol.82/3 (Septembre 2016) . - p. 516-521
[article] Are there differences in Hip Biomechanics after hybrid and cementless resurfacing arthroplasty? [texte imprimé] / Michel J. Le Duff ; Sandeep K. Bhaurla ; Kohtaroh B. Takamura ; Harlan Amstutz (C.) . - 2016 . - p. 516-521. Langues : Anglais ( eng) in Acta Orthopaedica Belgica > Vol.82/3 (Septembre 2016) . - p. 516-521
Mots-clés : |
arthroplastie hanche |
Résumé : |
There is a paucity of information regarding the clinical performance of the fully cementless metalon-metal hip resurfacing designs. We compared the biomechanical reconstruction between the two hips of a group of patients treated with a hybrid resurfacing design on one side and a new, fully cementless version of the same resurfacing design on the other side. We retrospectively identified 20 patients with a hybrid hip resurfacing on one side and a fully cementless device on the contralateral side. The cemented femoral components were implanted with a target angle stem to shaft angle of 140° while the cementless femoral components were implanted with the aim to replicate the natural neck to shaft angle. No significant differences were observed postoperatively in femoral offset or leg length despite implantation with a larger metaphyseal stem to femoral shaft angle in the hybrid group. Both hybrid and cementless designs provide similar biomechanical reconstructions. |
Permalink : |
./index.php?lvl=notice_display&id=47179 |
|  |
Exemplaires (1)
|
Revue | Revue | Centre de Documentation HELHa Campus Montignies | Armoires à volets | Document exclu du prêt - à consulter sur place Exclu du prêt |