[article]
Titre : |
Gait analysis in tumor patients after distal femoral resection and implantation of a megaprosthesis |
Type de document : |
texte imprimé |
Auteurs : |
J. Bruns ; K. Raabe ; G. Deuretzbacher |
Année de publication : |
2016 |
Article en page(s) : |
p. 287-297 |
Langues : |
Anglais (eng) |
Mots-clés : |
ostéosarcome os tumeur analyse de la marche fémur prothèse |
Résumé : |
We analysed nine patients who had had a megaprosthesis implanted into the distal femur and knee joint for treatment of sarcomas. Data obtained from the leg operated on were compared with those from the contralateral side and healthy volunteers. Gait data, kinematics, ground reaction forces and the EMG from five muscles around the knee joint were analysed by means of a video-based analysis system recording data from reflection markers ; a Kistlerplate recorded the GRF and a ten channel surface EMG the muscle activity. Muscle around the knee showed a cocontraction between the extensor and flexor muscles in the thigh and the calf in the operated leg as well as contralaterally. Gait characteristics exhibited a reduced speed, cadence, and a shorter step. This correlated with a reduced flexion in the hip and knee joint. The GRF exhibited significant changes in the data representing the reduced gait dynamic. |
Permalink : |
./index.php?lvl=notice_display&id=46096 |
in Acta Orthopaedica Belgica > Vol.82/2 (June 2016) . - p. 287-297
[article] Gait analysis in tumor patients after distal femoral resection and implantation of a megaprosthesis [texte imprimé] / J. Bruns ; K. Raabe ; G. Deuretzbacher . - 2016 . - p. 287-297. Langues : Anglais ( eng) in Acta Orthopaedica Belgica > Vol.82/2 (June 2016) . - p. 287-297
Mots-clés : |
ostéosarcome os tumeur analyse de la marche fémur prothèse |
Résumé : |
We analysed nine patients who had had a megaprosthesis implanted into the distal femur and knee joint for treatment of sarcomas. Data obtained from the leg operated on were compared with those from the contralateral side and healthy volunteers. Gait data, kinematics, ground reaction forces and the EMG from five muscles around the knee joint were analysed by means of a video-based analysis system recording data from reflection markers ; a Kistlerplate recorded the GRF and a ten channel surface EMG the muscle activity. Muscle around the knee showed a cocontraction between the extensor and flexor muscles in the thigh and the calf in the operated leg as well as contralaterally. Gait characteristics exhibited a reduced speed, cadence, and a shorter step. This correlated with a reduced flexion in the hip and knee joint. The GRF exhibited significant changes in the data representing the reduced gait dynamic. |
Permalink : |
./index.php?lvl=notice_display&id=46096 |
|  |
Exemplaires (1)
|
Revue | Revue | Centre de Documentation HELHa Campus Montignies | Armoires à volets | Document exclu du prêt - à consulter sur place Exclu du prêt |