[article]
Titre : |
Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years |
Type de document : |
texte imprimé |
Auteurs : |
Martin Ellenrieder ; Rainer Bader ; Philipp Bergschmidt ; Wolfram Mittelmeier |
Année de publication : |
2016 |
Article en page(s) : |
p. 60-67 |
Langues : |
Anglais (eng) |
Mots-clés : |
hanche prothèse |
Résumé : |
Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group : n = 42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p = 0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred. |
Permalink : |
./index.php?lvl=notice_display&id=46045 |
in Acta Orthopaedica Belgica > Vol.82/1 (March 2016) . - p. 60-67
[article] Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years [texte imprimé] / Martin Ellenrieder ; Rainer Bader ; Philipp Bergschmidt ; Wolfram Mittelmeier . - 2016 . - p. 60-67. Langues : Anglais ( eng) in Acta Orthopaedica Belgica > Vol.82/1 (March 2016) . - p. 60-67
Mots-clés : |
hanche prothèse |
Résumé : |
Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group : n = 42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p = 0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred. |
Permalink : |
./index.php?lvl=notice_display&id=46045 |
|  |
Exemplaires (1)
|
Revue | Revue | Centre de Documentation HELHa Campus Montignies | Armoires à volets | Document exclu du prêt - à consulter sur place Exclu du prêt |