[article]
Titre : |
Evaluation of implant alignment in navigated unicompartmental knee arthroplasty : a comparison of 2D and 3D imaging |
Type de document : |
texte imprimé |
Auteurs : |
Kazunari Ishida ; Akihiko Toda ; Nao Shibanuma |
Année de publication : |
2015 |
Article en page(s) : |
p.654-661 |
Langues : |
Anglais (eng) |
Résumé : |
This study aimed to compare two-dimensional (2D) and three-dimensional (3D) methods for evaluating implant alignment in navigated UKA. Nineteen UKAs in 18 subjects (7 men) were performed using an image- free navigation system. Coronal and sagittal implant alignments were assessed using radiographs (2D evaluation) and 3D image-matching software. The accuracy of 2D evaluation was compared with that of 3D evaluation. A deviation > 3° from the 3D evaluation was defined as an outlier. In the 2D evaluation, outliers for the femoral component were observed in both the coronal plane (6/19 subjects) and the sagittal plane (3/19 subjects). In UKA, assessment of the implant position might be misjudged because of the design of the implant, especially for the femoral component ; 3D methods are ideal for assessment of implant alignment. |
Permalink : |
./index.php?lvl=notice_display&id=42347 |
in Acta Orthopaedica Belgica > Vol.81/4 (Décembre 2015) . - p.654-661
[article] Evaluation of implant alignment in navigated unicompartmental knee arthroplasty : a comparison of 2D and 3D imaging [texte imprimé] / Kazunari Ishida ; Akihiko Toda ; Nao Shibanuma . - 2015 . - p.654-661. Langues : Anglais ( eng) in Acta Orthopaedica Belgica > Vol.81/4 (Décembre 2015) . - p.654-661
Résumé : |
This study aimed to compare two-dimensional (2D) and three-dimensional (3D) methods for evaluating implant alignment in navigated UKA. Nineteen UKAs in 18 subjects (7 men) were performed using an image- free navigation system. Coronal and sagittal implant alignments were assessed using radiographs (2D evaluation) and 3D image-matching software. The accuracy of 2D evaluation was compared with that of 3D evaluation. A deviation > 3° from the 3D evaluation was defined as an outlier. In the 2D evaluation, outliers for the femoral component were observed in both the coronal plane (6/19 subjects) and the sagittal plane (3/19 subjects). In UKA, assessment of the implant position might be misjudged because of the design of the implant, especially for the femoral component ; 3D methods are ideal for assessment of implant alignment. |
Permalink : |
./index.php?lvl=notice_display&id=42347 |
|  |