Centre de Documentation Campus Montignies
Horaires :
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Bienvenue sur le catalogue du centre de documentation du campus de Montignies.
[article]
Titre : |
Evaluation Of Prominence Of Straight Plates And Precontoured Clavicle Plates Using Automated Plate-To-Bone Alignment |
Type de document : |
texte imprimé |
Auteurs : |
Alexander Van Tongel, Auteur |
Année de publication : |
2014 |
Article en page(s) : |
p.301-308 |
Langues : |
Anglais (eng) |
Mots-clés : |
clavicle fracture hardware irritation precontoured plates 3D reconstruction automated fitting |
Résumé : |
Hardware prominence after plate fixation for clavicle fractureis a common complication. The aim of the study was to perform a 3D analysis of the prominence of different types of superior clavicle plates. An automated fitting of 3 straight and 10 precontoured plates was performed on 52 3D-CT-scan reconstructed cadaver clavicles. The mean and maximum bone-plate distance and maximum prominence was significant higher with the straight plates compared to the precontoured plates. The mean and maximum boneplate distance was significant higher with the precontoured DePuy-Synthes plates compared to the precontoured Acumed plates but when evaluating the maximum prominence there was no significant difference between the most commonly used 8-holes plates. To conclude, precontoured plates of the clavicula diminish significantly hardware prominence. There exists a difference in hardware prominence between different brands of precontoured plates but this difference is limited and in most cases not significant. |
Permalink : |
./index.php?lvl=notice_display&id=34643 |
in Acta Orthopaedica Belgica > Vol 80/3 (Septembre 2014) . - p.301-308
[article] Evaluation Of Prominence Of Straight Plates And Precontoured Clavicle Plates Using Automated Plate-To-Bone Alignment [texte imprimé] / Alexander Van Tongel, Auteur . - 2014 . - p.301-308. Langues : Anglais ( eng) in Acta Orthopaedica Belgica > Vol 80/3 (Septembre 2014) . - p.301-308
Mots-clés : |
clavicle fracture hardware irritation precontoured plates 3D reconstruction automated fitting |
Résumé : |
Hardware prominence after plate fixation for clavicle fractureis a common complication. The aim of the study was to perform a 3D analysis of the prominence of different types of superior clavicle plates. An automated fitting of 3 straight and 10 precontoured plates was performed on 52 3D-CT-scan reconstructed cadaver clavicles. The mean and maximum bone-plate distance and maximum prominence was significant higher with the straight plates compared to the precontoured plates. The mean and maximum boneplate distance was significant higher with the precontoured DePuy-Synthes plates compared to the precontoured Acumed plates but when evaluating the maximum prominence there was no significant difference between the most commonly used 8-holes plates. To conclude, precontoured plates of the clavicula diminish significantly hardware prominence. There exists a difference in hardware prominence between different brands of precontoured plates but this difference is limited and in most cases not significant. |
Permalink : |
./index.php?lvl=notice_display&id=34643 |
|  |
Exemplaires (1)
|
Revue | Revue | Centre de Documentation HELHa Campus Montignies | Réserve | Consultable sur demande auprès des documentalistes Exclu du prêt |