Centre de Documentation Campus Montignies
Horaires :
Lundi : 8h-18h30
Mardi : 8h-18h30
Mercredi 9h-16h30
Jeudi : 8h-18h30
Vendredi : 8h-16h30
Bienvenue sur le catalogue du centre de documentation du campus de Montignies.
[article]
Titre : |
Interrater reliability and clinical utility of the Personal Care Participation Assessment and Resource Tool (PC-PART) in an inpatient rehabilitation setting |
Type de document : |
texte imprimé |
Auteurs : |
Camilla RADIA-GEORGE ; Christine Imms ; Nicholas F. Taylor |
Année de publication : |
2014 |
Article en page(s) : |
334-343 |
Langues : |
Anglais (eng) |
Résumé : |
OBJECTIVE:
We examined the interrater reliability and clinical utility of the Personal Care Participation Assessment and Resource Tool (PC-PART) in a rehabilitation setting.
METHOD:
Ninety-six patients were recruited from the caseload of four occupational therapists. Patients were assessed on admission. Clinical utility was based on time to complete assessments.
RESULTS:
Interrater reliability for the total score was very high (intraclass correlation coefficient = .91). Limits of agreement for the program indicated aggregate data from individual scores were within 1.3 units (range = -1.3 to 0.5) but individual scores would be within 10 units (range = -9.3 to 0.2). The PC-PART took 27 min to complete.
CONCLUSION:
The PC-PART may have sufficient interrater reliability and clinical utility to evaluate program outcomes. The limits of agreement for rating individuals were relatively large, suggesting that it may be difficult to use the PC-PART to make clinical inferences about an individual patient. |
Permalink : |
./index.php?lvl=notice_display&id=33761 |
in American Journal of Occupational Therapy > Vol. 68/3 (mai-juin 2014) . - 334-343
[article] Interrater reliability and clinical utility of the Personal Care Participation Assessment and Resource Tool (PC-PART) in an inpatient rehabilitation setting [texte imprimé] / Camilla RADIA-GEORGE ; Christine Imms ; Nicholas F. Taylor . - 2014 . - 334-343. Langues : Anglais ( eng) in American Journal of Occupational Therapy > Vol. 68/3 (mai-juin 2014) . - 334-343
Résumé : |
OBJECTIVE:
We examined the interrater reliability and clinical utility of the Personal Care Participation Assessment and Resource Tool (PC-PART) in a rehabilitation setting.
METHOD:
Ninety-six patients were recruited from the caseload of four occupational therapists. Patients were assessed on admission. Clinical utility was based on time to complete assessments.
RESULTS:
Interrater reliability for the total score was very high (intraclass correlation coefficient = .91). Limits of agreement for the program indicated aggregate data from individual scores were within 1.3 units (range = -1.3 to 0.5) but individual scores would be within 10 units (range = -9.3 to 0.2). The PC-PART took 27 min to complete.
CONCLUSION:
The PC-PART may have sufficient interrater reliability and clinical utility to evaluate program outcomes. The limits of agreement for rating individuals were relatively large, suggesting that it may be difficult to use the PC-PART to make clinical inferences about an individual patient. |
Permalink : |
./index.php?lvl=notice_display&id=33761 |
|  |
Exemplaires (1)
|
Revue | Revue | Centre de Documentation HELHa Campus Montignies | Réserve | Consultable sur demande auprès des documentalistes Exclu du prêt |