Titre : |
Interinstrument reliability of the jamar electronic dynamometer and pinch gauge compared with the Jamar hydraulic dynamometer and B&L Engineering mechanical pinch gauge. |
Type de document : |
texte imprimé |
Auteurs : |
Theodore I. KING |
Année de publication : |
2013 |
Article en page(s) : |
p. 480-483 |
Langues : |
Anglais (eng) |
Mots-clés : |
Force musculaire Main Evaluation |
Résumé : |
OBJECTIVE. This study sought to determine interinstrument reliability of the Jamar electronic dynamometer and pinch gauge compared with the commonly used Jamar hydraulic dynamometer and B&L Engineering mechanical pinch gauge. METHOD. Twenty men and 20 women were tested for grip strength with the two different dynamometers, and 17 men and 25 women were tested for lateral pinch strength with the two different pinch gauges. RESULTS. Grip strength measurements were approximately 10% higher with the hydraulic dynamometer, and lateral pinch strength measurements were approximately 18% higher with the mechanical pinch gauge. Paired t tests and intraclass correlation coefficients (ICCs) were used for statistical analyses. The two-tailed p value was <.0001, and the ICC indicated poor to moderate reliability. CONCLUSION. When retesting patients, it is recommended that occupational therapists use the same instrument to measure hand strength because interinstrument reliability may be lacking. |
Permalink : |
./index.php?lvl=notice_display&id=14129 |
in American Journal of Occupational Therapy > Vol. 67/4 (juillet-aout 2013) . - p. 480-483
[article] Interinstrument reliability of the jamar electronic dynamometer and pinch gauge compared with the Jamar hydraulic dynamometer and B&L Engineering mechanical pinch gauge. [texte imprimé] / Theodore I. KING . - 2013 . - p. 480-483. Langues : Anglais ( eng) in American Journal of Occupational Therapy > Vol. 67/4 (juillet-aout 2013) . - p. 480-483
Mots-clés : |
Force musculaire Main Evaluation |
Résumé : |
OBJECTIVE. This study sought to determine interinstrument reliability of the Jamar electronic dynamometer and pinch gauge compared with the commonly used Jamar hydraulic dynamometer and B&L Engineering mechanical pinch gauge. METHOD. Twenty men and 20 women were tested for grip strength with the two different dynamometers, and 17 men and 25 women were tested for lateral pinch strength with the two different pinch gauges. RESULTS. Grip strength measurements were approximately 10% higher with the hydraulic dynamometer, and lateral pinch strength measurements were approximately 18% higher with the mechanical pinch gauge. Paired t tests and intraclass correlation coefficients (ICCs) were used for statistical analyses. The two-tailed p value was <.0001, and the ICC indicated poor to moderate reliability. CONCLUSION. When retesting patients, it is recommended that occupational therapists use the same instrument to measure hand strength because interinstrument reliability may be lacking. |
Permalink : |
./index.php?lvl=notice_display&id=14129 |
|  |
Exemplaires (1)
|
Revue | Revue | Centre de Documentation HELHa Campus Montignies | Réserve | Consultable sur demande auprès des documentalistes Exclu du prêt |